  • Input Current : 3.5A
  • Input Voltage : 115VAC
  • Output Current : 6A

Description

Altronix AL600ULM Multi-Output Power Supply/Chargers

AL600ULM multi-output access control power supply/charger is specifically designed for use with access control systems and accessories. This unit converts a 115VAC, 60Hz input into five (5) individually protected Class 2 Rated power limited 12VDC or 24VDC outputs. Each output will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. These outputs will operate in both Fail-Safe and Fail-Secure modes. Controlled trigger input is achieved through normally open (N.O.) or normally closed (N.C.) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay enables HVAC Shutdown, Elevator Recall or it may be used to trigger auxiliary devices.

Key Features Of Altronix AL600ULM

Input

  • Input 115VAC, 60Hz, 3.5A.
  • Input fuse rated @ 3.5A/250V.
  • Fire Alarm Panel or Access Control System trigger inputs. N.O. or N.C.supervised trigger input and polarity reversal trigger input.

Output

  • 12VDC or 24VDC selectable outputs.
  • 6A supply current.
  • Five (5) PTC protected Class 2 Rated power limited outputs, rated @ 2A (auto-resettable).
  • Output relay energizes when unit is triggered (form "C" contact rated 1A. @ 28VDC).
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.

Battery Backup

  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.

Supervision

  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery supervision (form "C" contacts).
  • Battery presence supervision (form "C" contacts).
  • Power fail supervision relay (form "C" contacts).

Visual Indicators

  • AC input and DC output LED indicators (power supply board).
  • Red LEDs indicate condition of power outputs (multi-output board).
  • Power & input trigger LEDs (multi-output board).

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F).
  • Storage: - 20° C to 70° C ( - 4° F to 158° F).
  • Relative Humidity 85% +/- 5%.

BTU/Hr (approx.):

  • 12VDC: 37 BTU/Hr.
  • 24VDC: 74 BTU/Hr.
  • System AC input VA requirement: 166.75VA.

Additional Information

Accessory Type:
Power Supply
Compliance:
NDAA Compliant
Input Current:
3.5A
Input Voltage:
115VAC
Output Current:
6A
Warranty:
Life-time Warranty