Altronix Maximal1RHDV Access Power Controller with Power Supply/Charger - 8 PTC Class 2 Relay Outputs

(No reviews yet) Write a Review
SKU:
Maximal1RHDV
$385.32
Free Shipping
Frequently bought together:

Description

Altronix Maximal1RHDV Access Power Controller with Power Supply/Charger - 8 PTC Class 2 Relay Outputs

Maximal1RHDV rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into eight (8) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by a normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.

Key Features:

  • Input
    • 220VAC (working range 198VAC - 256VAC), 50/60Hz, 1.0A.
    • Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable).
  • Outputs
    • 12VDC @ 4A or 24VDC @ 3A total output current.
    • Eight (8) PTC protected outputs (auto-resettable).
    • Maximum current per ACM8R-M output is 2A.
    • Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state fuse protected outputs.
    • Thermal and short circuit protection with auto reset.
  • Fire Alarm Interface
    • Latching or Non-Latching fire alarm reset switch individually selectable for each output.
    • Remote reset capability for latching Fire Alarm Interface mode.
      • Fire Alarm disconnect input options:
        • a) Normally open [NO] or normally closed [NC] dry contact input.
        • b) Polarity reversal input from FACP signaling circuit.
  • Visual Indicators
    • Individual Output Status LEDs located on the front panel.
  • Battery Backup
    • Built-in charger for sealed lead acid or gel type batteries (if batteries are required, install separate enclosure).
    • Automatic switch over to stand-by battery when AC fails.
    • Zero voltage drop when unit switches over to battery backup (AC failure condition).
  • Supervision
    • AC fail supervision (form "C" contacts).
    • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
    • Low battery and battery presence supervision (form "C" contact).
  • Additional Features
    • Removable terminal blocks with locking screw flange.
    • 3-wire line cord.
    • Illuminated master power disconnect circuit breaker with manual reset.
  • Electrical
      • Temperature:
        • Operating: 0° C to 49° C (32° F to 120° F).
        • Storage: - 20° C to 70° C ( - 4° F to 158° F).
    • Relative Humidity 85% +/- 5%.
      • BTU/Hr (approx.):
        • 12VDC: 25 BTU/Hr.
        • 24VDC: 37 BTU/Hr.